General description of the thermostat
HKT-008 heat pipe thermostat tank, in line with JJG 130 calibration regulations and other requirements of the thermostat tank, suitable for a variety of glass liquid
thermometer, bimetal thermometer, fiber optic temperature sensor, thermocouple and temperature sensor calibration and verification, can be used in place of other
thermostat tanks such as oil tanks, salt tanks and other thermostat tanks. It can do full immersion, local immersion thermometer calibration and verification. on December
30, 2015 had been awarded the Certificate of Utility Model Patent.
Type 1 Measuring range: 90℃~200℃; Type 2 Measuring range: 200℃~400℃;
Type 3 Measuring range: 300℃~500℃; Type 4 Measuring range: 60℃~150℃.
Functional features
1. Automatic temperature control, digital display with high sensitivity of 0.01℃.
2. Small temperature fluctuation, uniform and stable temperature field
3. Fast heating speed, from room temperature to 300 ℃ about 40min, up to 400 ℃ about 60min
4. No need to replace the working medium, the system is fully sealed, no flavor, no sound, no pollution of the environmen
5. Easy to operate, the temperature is set, the automatic operation of temperature control. The whole box can be rotated 360 °, convenient for thermometer readings
6. Long service life, generally can be used for more than 10 years
Technical parameters
1. Temperature fluctuation and temperature field uniformity
Temperature fluctuation: 60 ℃ ~ 150 ℃; ≤ 0.04 ℃
Temperature field uniformity:
a. The working area of the horizontal temperature difference ≤ 0.02 ° C
b. Maximum temperature difference in the working area ≤0.04℃.
Temperature fluctuation: 90 ℃ ~ 200 ℃; ≤ 0.04 ℃
Temperature field uniformity:
a. Work area horizontal temperature difference ≤ 0.02 ℃
b. Maximum temperature difference in the working area ≤ 0.04 ℃
Temperature fluctuation: 200 ℃ ~ 400 ℃; ≤ 0.10 ℃
Temperature field uniformity:
a. Working area horizontal temperature difference ≤ 0.04 ℃
b. Maximum temperature difference in the working area ≤ 0.08 ℃
Temperature fluctuation: 300 ℃ ~ 500 ℃; ≤ 0.20 ℃
Temperature field uniformity:
a. Working area horizontal temperature difference ≤ 0.10 ℃
b. Maximum temperature difference in the working area ≤ 0.20 ℃
2. Number of temperature measuring tubes: 8 (can be customized according to user requirements)
3. Diameter of temperature measuring tubes: 2 10mm, 6 8mm (can be customized according to user requirements)
4. Depth of working area: 460mm (glass liquid thermometer)
5. Temperature control sensor: Pt100 platinum resistance
Note:
1. When the input voltage is unstable, to ensure the accuracy of the temperature field of the heat pipe tank, it is recommended to be equipped with a regulated power supply. Regulated power supply requirements: accuracy of not more than 220V ± 1%, load greater than or equal to 10kW.
2, according to user requirements, design and production of different specifications of the heterogeneous heat pipe thermostat tank.



Thermometer Name Temperature Measurement Range
Copyright © 2025 Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.